• Home
  • About Us
  • Services
  • List of validation tests
    • Overview
    • Biocompatibility
    • Dental Material
    • Laser and LED Safety
    • Sterilization / Packaging
    • Usability-2
  • Software
  • Cleaning
  • Contact Us
  • Home
  • About Us
  • Services
  • List of validation tests
    • Overview
    • Biocompatibility
    • Dental Material
    • Laser and LED Safety
    • Sterilization / Packaging
    • Usability-2
  • Software
  • Cleaning
  • Contact Us

Comprehensive Nonclinical Testing Services for Medical Devices

Biocompatibility & Toxicology (ISO 10993 Series)

  • Cytotoxicity (ISO 10993-5)
  • Sensitization (ISO 10993-10)
  • Irritation & Intracutaneous Reactivity
  • Acute, subacute, subchronic, and chronic systemic toxicity
  • Genotoxicity (Ames test, chromosomal aberration)
  • Carcinogenicity studies
  • Reproductive & developmental toxicity (ISO 10993-3)
  • Hemocompatibility (ISO 10993-4)
  • Implantation studies
  • Pyrogenicity (rabbit test, LAL)
  • Chemical characterization (ISO 10993-18)
  • Toxicological risk assessment (ISO 10993-17)


Dental Material Testing

  • Compressive & flexural strength (ISO 4049, ISO 9917-1)
  • Wear resistance and hardness
  • Water sorption and solubility
  • Bond strength to tooth structure (shear, tensile)
  • Color stability and optical properties
  • Radiopacity testing (ISO 6876, ISO 4049)
  • Biocompatibility and cytotoxicity specific to oral mucosa
  • Surface roughness and polishability
  • Fluoride release (for glass ionomer cements)
  • Thermocycling resistance testing
  • Adhesive/dentin interface testing
  • Antimicrobial activity of dental materials


Laser and LED Device Testing

  • IEC 60825-1: Laser safety classification & labeling
  • IEC 60601-2-22: Particular requirements for medical lasers
  • LED emission testing and photobiological safety
  • Wavelength verification and energy output testing
  • Beam profile and divergence analysis
  • Hazard zone mapping
  • Eye safety and retinal exposure assessments
  • Skin exposure and thermal hazard testing
  • Fiber-optic and delivery system safety
  • Compliance with ANSI Z136 laser safety standards
  • IEC 62471: Photobiological safety of lamps and lamp systems (for LED/UV devices)


Microbiological Testing & Sterilization Validation

  • Bioburden testing (ISO 11737-1)
  • Sterility testing (USP <71>)
  • Bacterial endotoxin (LAL testing)
  • Reprocessing validation (AAMI TIR30, ISO 17664)
  • EO residuals (ISO 10993-7)
  • Antimicrobial surface testing
  • Antiviral efficacy testing
  • Validation of cleaning/disinfection protocols
  • Validation of reusable device instructions


Material & Chemical Testing

  • Extractables and leachables (E&L studies)
  • Residual solvents (USP <467>)
  • Heavy metals and elemental impurities (ICP-MS, ICH Q3D)
  • FTIR, DSC, TGA, and other material characterization
  • Surface energy and adhesion testing
  • Particulate matter testing (USP <788>, <789>)
  • Corrosion and galvanic compatibility
  • Environmental stress cracking (ESC)

 

Mechanical & Performance Testing

  • Tensile, flexural, and fatigue testing
  • Simulated use and functional testing
  • Insertion and removal force (e.g., catheters, needles)
  • Trackability, torquability, and kink resistance
  • Burst, leak, and seal integrity
  • Valve performance and backflow testing
  • Actuation force (e.g., auto-injectors)
  • Wear and abrasion resistance
  • Sharpness and penetration force testing
  • Deployment/retraction testing for implants
  • Balloon compliance and burst testing


Packaging & Labeling Validation

  • Accelerated aging (ASTM F1980)
  • Real-time shelf-life studies
  • Seal strength testing (ASTM F88)
  • Dye ingress and bubble leak (ASTM F1929 / F2096)
  • Drop, vibration, and impact testing (ISTA/ASTM D4169)
  • Label legibility and adhesion testing
  • Tamper-evidence and traceability verification


Environmental, Thermal, and Transport Simulation

  • Thermal shock and temperature cycling
  • High/low humidity and temperature exposure
  • Altitude simulation
  • RTCA DO-160G for airborne equipment
  • UV and light exposure testing
  • Vibration testing (random, sine)
  • Drop testing for packaged products
  • Climatic chamber testing for storage stability


Electrical & Electromagnetic Compatibility

  • Electrical safety (IEC 60601-1)
  • EMC testing (IEC 60601-1-2)
  • MIL-STD-461
  • Wireless coexistence (per FDA guidance)
  • Battery testing (IEC 62133, UN 38.3)
  • Electrical leakage, insulation resistance, and grounding tests


Specialized Device-Specific Tests

  • MRI safety and artifact testing (ASTM F2503)
  • Joint simulation testing for orthopedic implants
  • Flow rate and occlusion testing (e.g., infusion pumps)
  • Intraocular lens testing (ISO 11979 series)
  • Hearing aid/acoustic testing (IEC 60118)
  • Endoscope durability testing (twist, bend, flex)
  • Ophthalmic instrument testing (ISO 15004)
  • Alarm systems (IEC 60601-1-8)
  • Infusion pump alarm and safety testing

Let’s Ensure Compliance Together — Get in Touch Today.

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

Copyright © 2025 Cert-Med LLC - All Rights Reserved.